lint traps

service thumb

LINT TRAP

INTRODUCTION

RSK-LT lint traps are standard compliant:

Uniform Plumbing Code (UPC)

 

  • The RSK-LT lint traps are completely weatherproof and are intended for separating sediment, sand and lint from wastewater.
  • The raw materials used are stainless steel or iron coated with epoxy (acidifier), which ensures high mechanical resistance and corrosion protection.
  • The production of equipment under controlled conditions, the use of high-quality raw materials and the inspection of the final product, in accordance with the requirements of the ISO 9001 standard, guarantee the quality of the final product.

 

ADVANTAGES

  • Heavy duty materials.
  • Protection Cover with non-odor safety.
  • High storage capacity for separated products.
  • High mechanical resistance and corrosion protection.
  • Easy to install and maintain.
  • Totally watertight.
  • Without power consumption.
  • Low cost.
  • Without odors with a correct ventilation.
  • Available with two kinds of materials:
  1. Made of stainless steel 304 L / 316 L.
  2. Made of Acid Resistant Epoxy Coated Steel.

 

APPLICATION      

The wastewater produced in laundries are full of lint and sands that interfere with drainage systems and sewage treatment.

 

 

DESIGN & OPERATION

The RSK-LT is designed to remove sediment, sand and lint from wastewater.

Lint Traps prevent sediment, sand and lint from entering plumbing systems to prevent clogging.

Primarily located right after laundry or on drain lines connected to central laundries, properly located and maintained interceptors keep drain systems free of problematic lint buildup.

The interception process is carried out through successive barriers that prevent the passage of suspended materials in the water.

The size of the product is estimated by the number of washing machines.

 

Uniform Plumbing Code (UPC)

CHART H 901.7

RECOMMENDED DESIGN CRITERIA:

 

SILT-LINT GREASE, LAUNDRIES, LAUNDROMATS

Number of

machines

X

2 cycles

Per hour

X

Waste

Flow rate

X

Retention time

=

Storage

factor

=

Interceptor size

(Liquid capacity)

NOTE:

Retention Times: Lint-silt (laundry):                    2.0 hours

Storage Factors: Laundries, laundromats:                    1.5 (allows for rock filter)

 

MATERIALS

  • Stainless Steel (-SS):

For good general corrosion resistance and stability against intracrystalline corrosion effects of the various steels listed in the EN 10088-1, EN 10088-2 and EN 10088-3, only used austenitic steels (304L - 316L)

Interceptor bodies are 11 ga. cold rolled steel, with an oven cured, acid resistant baked grey epoxy coating, inside and out. Standard cover is epoxy coated.

 

 

 

 

Engineering Specification

FLOW CONTROL FITTING:

Flow control fittings ensure 90% or more retention efficiency of the interceptor.

When consideration isn’t given to the flow rate of the waste water to be handled, the actual flow rate through the interceptor usually exceeds its rated maximum.

With such flow rate, the interceptor would be overloaded. Retention time within the unit would not be sufficient for maximum separation.

The result would be low efficiency, and pollutants left in the waste water would pass through the interceptor, making the installation less than effective.

When the flow is controlled by use of a flow control fitting so that it can never exceed the maximum rating of the interceptor, and the interceptor is cleaned on a regular basis, the maximum pollutant retention efficiency will be achieved and maintained.

All flow control fittings are built with an air intake and should be connected to the vent stack or vent not lower than the flow level of the highest drain serviced or terminated in a return bend at the same elevation outside of the building.

A vented flow control fitting improves the efficiency of the grease interceptor by introducing air into the body of the interceptor.

 

 

NO HUB PIPE

CONNECTION SIZE

ORIFICE SIZE

VENT CONNECTION

SIZE

2” (52)

0.375” (9)

2” (50)

2” (52)

0.500” (13)

2” (50)

2” (52)

0.656” (16)

2” (50)

2” (52)

0.750” (19)

2” (50)

3” (75)

1.000” (25)

2” (50)

3” (75)

1.250” (31)

2” (50)

3” (75)

1.250” (31)

2” (50)

3” (75)

2.000” (50)

2” (50)

4” (102)

2.000” (50)

2” (50)

4” (102)

2.250” (57)

2” (50)

 

Installation considerations

  • Install the trap as close as practicable to the fixture or fitting being provided.
  • The trap may be installed on the floor, partially enclosed in the floor, flush with the floor, or completely recessed under the floor to suit piping and structural conditions.
  • Make sure to keep enough space to remove the trap cover for cleaning.
  • Avoid installation in locations where long pipes (over 25 feet (7500)) are necessary to reach the trap.
  • Do not install the trap in the waste line (grey water).
  • Garbage mill waste must exceed the trap, because the rapid build-up of solids will greatly reduce the efficiency of lint interception preventing operation at rated capacity.

flow control

  • Traps compatible with flow control should be installed before the interceptor in the washing line after the last connection of the fixture and as close as possible to the underside of the lowest fixture.
  • When two or more sinks or fixtures are combined to be served by a single trap, single flow control fixtures must be used.
  • The flow control air inlet may terminate under the sump drain plate as high as possible to prevent overflow or terminate in a return curve at the same height and outside the building.
  • When fittings are individually enclosed and rear ventilated, the air inlet may intersect with the vent.
  • All installation recommendations are subject to code authority approval.

ventilation

Traps shall have ventilation holes, sized to comply with code requirements for venting traps to retain a water seal and prevent excessive pressure within the trap.

Multiple unit installation

It is recommended to use one device to service multiple installations only when the installations are close to each other. In such installations, each unit must be individually enclosed and rear ventilated.

 

 

MAINTENANCE

 

GENERAL CONSIDERATIONS:

To obtain optimum operating efficiency of a properly sized and installed interceptor, a regular schedule of maintenance must be adhered.

Interceptors are furnished with manufacturer’s operating and maintenance instructions, which must be followed to ensure efficient satisfactory operation.

 

CLEANING:

All interceptors must be cleaned regularly. The frequency of lint removal is dependent upon the capacity of the interceptor and the quantity of lint in the waste water.

Lint removal intervals may therefore vary from once a week to once in several weeks.

When the lint removal interval has been determined for a specific installation, regular cleaning at that interval is necessary to maintain the rated efficiency of the interceptor.

After the accumulated lint and obstructions has been removed, the interceptor should be thoroughly checked to make certain that inlet, outlet and air relief ports are clear of obstructions.

 

DISPOSITION OF INTERCEPTED MATERIALS:

The waste matter that has been removed from the interceptor should not be introduced into any drain, sewer, or natural body of water.

This waste matter should be placed in proper containers for disposal.

 

 

Warranty Policy

warranty period:

From the date of installation

• Warranty period of 2 years for the product body, Includes leakage and damage from manufacturing.

• Providing supplies and spare parts for a period of five years.

 

Warranty Policy:

 General rules and conditions:

1. The original contract must be provided.

2. Warranty means that the product has been approved for repair, Replacement is only for products that cannot be repaired, and in the event of a manufacturing defect in the product, within six days from the date of installation, the product can be exchanged or returned.

3. The product must be within the warranty period, and under the original sales invoice.

4. The warranty covers any manufacturing defect of the product, and does not include any malfunction caused by misuse.

5. The warranty does not cover consumables that must be replaced or replaced periodically.

6. Warranty is voided in case the product is serviced at centers not approved by Rusukh.

7. Installation, operation and periodic maintenance is carried out (for a company/companies) officially approved by Rusukh Company.

8. The warranty does not include any additional damage resulting from the delay in reporting to request a product repair.

Rusukh
Typically replies within minutes

Rusukh
hello

how can we help you?
1:40
×
Contact us